用途场景

研发 实验室研发、新产品开发、技术研究
生产 生产线检测、工艺控制、制造过程监控
品控 质量检验、来料检测、成品测试
合规认证 计量检测、仪器校准、精度验证
教学实训 教学实验、技能培训、实训演示
维修 设备维修、故障诊断、维护保养

规格参数

产品概述

Broad, versatile workload coverage

The 96040A calibrates a broad workload of RF calibration devices, including:

• Spectrum analyzers

• Modulation meters and analyzers

• RF power meters and sensors

• Frequency counters

• Attenuators

• And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The 96040A replaces all of these parts of a “typical” RF calibration system:

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

  • Power meters and power sensors
  • Step attenuators
  • Filters
  • Pads
  • Couplers
  • 50 MHz frequency counter

The 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4 GHz, you can use an RF and microwave source that you probably already own alongside the 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4 GHz, you only need a 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts or dBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power and dBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the DUT error is displayed directly in dB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers 96040A signal levels directly to the device under test (DUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10 MHz offsets, the 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a DUT to be frequency locked to the 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the DUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5 GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the 96040A, used with MET/CAL Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution.

技术规格

96040A summary specifications*
Frequency specificationsLevel specifications
(50 Ω output, see extended specifications for 75 Ω)
Range1 mHz to 4 GHz-130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)
Resolution10 µHz0.001 dB
Accuracy± 0.05 ppm ± 5 µHzDown to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm
Attenuation ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz
VSWR≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)
Harmonics and spurious–60 dBc harmonics, –78 dBc spurious to 1 GHz
Phase noise at 1 GHz–144 dBc/Hz, typical, at 10 kHz to 100 kHz offset
ModulationAM, FM, PM, internal and external. Frequency pull and external leveling
Frequency sweep1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span
Frequency counterInternal 50 MHz frequency counter
TemperatureOperating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.
Standard interfacesIEEE-488.2 (GPIB)
GPIB command emulation9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.
Dimensions (HxWxD)146 mm x 442 mm x 551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit
Weight18 kg (40 lb)
*Key specifications summary. Refer to the extended specifications for full and detailed specifications.

👀 你可能也感兴趣的 6

查看全部同类产品 →

选择嘉品的四大理由

22年行业积累,3000+客户信赖,构建仪器配套领域的专业服务体系

🎯

全品类一站式

16886款产品覆盖9大品类,150个国际品牌资源,从选型到配套一步到位,无需多头对接

  • 电学测试 / 力学可靠性 / 尺寸测量
  • 涂装检测 / 材料检测 / 行业专用
  • 实验室设备 / 仪器仪表配件耗材
🔬

专业技术团队

100+人的技术团队,涵盖售前咨询、方案设计、安装调试、售后维保全流程服务能力

  • 20+年行业经验资深工程师
  • GB/IEC/ISO标准体系深度理解
  • 53大行业配套实战经验
📊

数智化服务

在线选型、方案管理、设备档案、报修追踪,全流程数字化服务高效协同

  • 在线产品选型与方案配置
  • 设备电子档案与维保记录
  • 在线报修与工单追踪
🤝

快速响应保障

400服务热线1小时响应,重点区域24小时上门,备件库充足保障设备停机时间最短

  • 400-6886-456 全国服务热线
  • 1小时响应 / 24小时上门
  • 充足备件库 / 快速维修通道

全生命周期服务体系

从选型配套到维修保养,覆盖仪器设备全生命周期的一站式专业服务

📋

实验室整体规划

按行业标准与客户需求,提供从实验室布局、设备选型到安装调试的一站式整体方案,场景适配率≥98%。

🔧

非标定制设备

30%高级研发占比、100+专业技术团队,可按特殊需求定制液冷兼容试验箱等专用设备。

☁️

数智化服务

仪器选型、采购、使用、维保全流程线上化,工单可查、进度可视,效率提升80%。

🛠️

全周期售后服务

报修2小时响应,设备故障一次性修复率≥99%;定期保养提醒、精度校准、资产盘点。

📖

选购指南

覆盖环境可靠性、精密计量、材料分析等全品类仪器选型要点,帮您选对设备不踩坑。

🎓

嘉品课堂

定期开展技术培训与知识分享,提升团队仪器操作与维保技能。

服务流程

从需求沟通到售后维保,5步标准化服务保障方案落地

1

需求沟通

了解行业场景、检测标准与预算,专属顾问1对1对接

→
2

方案设计

匹配16886+款产品,24小时内输出完整配套方案

→
3

设备配套

精选150大优质品牌,支持非标定制,确保设备高适配

→
4

安装调试

工程师上门安装、联调、培训,确保设备顺利投产

→
5

售后维保

2小时快速响应,99%一次修复,终身技术支持

准备升级您的质检实验室?

全品类仪器一站式服务:53大行业配套方案、专业选型指南与全生命周期维保支持

或拨打服务热线 400-6886-456,专业技术团队1小时内响应

2026-11-18 01:23:04
在线客服
嘉品AI 客服中心 游客
您好,我是嘉品仪器客服 👋
有什么可以帮您?
🖼️
图片
📁
文件
✂️
截图
输入产品名称或型号AI自动回复,文字/图片/截图/文件都可发送,有问必答
↘
画笔模式:直接在图上涂鸦 · 裁剪模式:拖拽选区后点「应用裁剪」